| Type | In-line valve G1/4 | |||
| 3-position 5-way valve | External pilot | |||
| Illustrate | Medium voltage | |||
Main technical parameters
| Valve function | 32-A | 32-M | B52 | M52 | P53 | |||||||
| Normal position | C1) | P2) | H4) | C1) | P2) | H4) | - | - | C1) | P2) | E3) | |
| Stable position | Single electronic control | Dual electronic control | Single electronic control | |||||||||
| Reset method: air reset | Yes | No | - | No | No | |||||||
| Reset method: mechanical spring reset | No | Yes | - | Yes | Yes | |||||||
| Air port 1 vacuum operation | No | Only external pilot time | ||||||||||
| Design | Piston slide valve | |||||||||||
| Sealing principle | Soft | |||||||||||
| Drive mode | Electric | |||||||||||
| Control method | Pilot | |||||||||||
| Pilot air source | Internal or external | |||||||||||
| Exhaust function | With flow control | |||||||||||
| Nominal diameter [mm] | 5.7 | 7.3 | 6.9 | 6.5 | 6.3 | |||||||
| Rated flow [l/min] | 1000 | 1380 | 1300 | 1200 | 1000 | |||||||
| Flow rate on manifold plate [l/min] | 1000 | 1380 | 1300 | 1200 | 1000 | |||||||
| Switching time on/off [m s] | 13/27 | 15/22 | 10/45 | 15/48 | ||||||||
| Conversion time [m s] | - | 11 | - | 29 | ||||||||
| Valve width [mm] | 18 | |||||||||||
| Air port 1, 2, 3, 4,5 | G1/4 | |||||||||||
| Air port 12/14 | M5 | |||||||||||
| Product weight [g] | 164 | 164 | 154 | 160 | ||||||||
1) C=Normally closed/mid-closed type 2) P=Normally open/medium pressure type 3) E=Mid-discharge type 4) H=2x 3/2-way valve integrated in one housing, 1 x normally closed and 1 x normally open | ||||||||||||
| Electrical parameters | ||||||||||||
| Working voltage [V DC] | 5, 12, 24 ±10% | |||||||||||
| Power [W] | 1,By reducing the holding current function to 0.35 | |||||||||||
| Continuous power rate ED [%] | 100 | |||||||||||
| Protection class according to EN 60529 | IP40 (with socket), IP65 (for M8) | |||||||||||
| Working and environmental conditions | ||||||||||||
| Valve function | 32-A1) | 32-M3) | B52 | M52 | P53 | |||||||
| Working medium | Compressed air according to ISO 8573-2010 [7:4:4] | |||||||||||
| Work pressure Internal pilot [bar] | 1.5 … 8 | 3… 8 | 1.5 … 8 | 3… 8 | ||||||||
| Work pressure External pilot [bar] | 1.5 … 10 | –0.9 … 10 | ||||||||||
| Pilot pressure4) [bar] | 1.5 … 8 | 2 … 8 | 1.5 … 8 | 3… 8 | ||||||||
| Ambient temperature [°C] | –5 … +50, –5 … +60, with holding current reduction function | |||||||||||
| Medium temperature [°C] | –5 … +50, –5 … +60, with holding current reduction function | |||||||||||
1) Air reset 2) Mechanical spring return | ||||||||||||